4.6 BAFFLE INSTALLATION
4.6.1 Baffle installation and brick layout for Solution 3.4 model
All firebrick and ceramic wool baffles must be properly in place for correct burning operation.
Have any damaged firebricks replaced. Check the firebricks annually for damage and replace if
they are broken or damaged.
CERAMIC WOOL INSULATION
C-CAST BAFFLE
6" X 8" FIREBRICKS AT THE BACK
6" X 6" FIREBRICK
AT THE BACK
YELLOW
INSULATION PANELS
4-1/2" X 4-1/2" FIREBRICK
4-1/2" X 9" FIREBRICKS ON
SIDES AND BOTTOM
ASH PLUG
Figure 4.6.1 - Baffle installation and brick layout for Solution 3.4 model
The baffle on the left is not positionned correctly. The baffle on the right is positionned perfectly.
It must be on top of the bricks and at the rear of the unit.