45189A
Printed in Canada 17-10-2014
INSTALLATION
AND OPERATION
MANUAL
Solution 1.8
(EB00002 model)
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED WOOD
STOVE
Safety tested according to ULC S627
and UL 1482 Standards by
Intertek Testing Services
www.enerzone-intl.com
Stove Builder International Inc.
250, rue de Copenhague,
St-Augustin-de-Desmaures
(Quebec) Canada G3A 2H3
Tel: (418) 878-3040
Fax: (418) 878-3001
READ AND KEEP THIS MANUAL FOR REFERENCE
This manual is available for free download on the manufacturer’s web site. It is a
copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this
manual from time to time and cannot be responsible for problems, injuries, or damages
arising out of the use of information contained in any manual obtained from unauthorized
sources.
Przeglądanie stron 0
1 2 3 4 5 6 ... 55 56

Podsumowanie treści

Strona 1 - Solution 1.8

45189A Printed in Canada 17-10-2014 INSTALLATION AND OPERATION MANUAL Solution 1.8 (EB00002 model) US ENVIRONMENTAL PROTECTION AGENCY PHASE II CER

Strona 2

10 Solution 1.8 Installation and Operation Manual 2.3 The Benefits of Low Emissions and High Efficiency The low smoke emissions produced by the spec

Strona 3

Solution 1.8 Installation and Operation Manual 11 3 Fuel 3.1 Materials That Should Not be Burned • GARBAGE OF ANY KIND, • COAL OR CHARCOAL, • TR

Strona 4

12 Solution 1.8 Installation and Operation Manual 3.2.3 Log Length Logs should be cut about 1” (25 mm) shorter than the firebox so they fit in easily

Strona 5

Solution 1.8 Installation and Operation Manual 13 3.2.5 How to Dry Firewood Firewood that is not dry enough to burn is the cause of most complaints

Strona 6 - 1 Safety Information

14 Solution 1.8 Installation and Operation Manual You could buy a wood moisture meter to test your firewood. 3.3 Manufactured Logs Do not burn m

Strona 7 - 2 General Information

Solution 1.8 Installation and Operation Manual 15 Burn one or two small fires to begin the curing and conditioning process. Then build bigger and hot

Strona 8

16 Solution 1.8 Installation and Operation Manual Start by placing three or four full-sized split pieces of dry firewood in the firebox. Next, place

Strona 9

Solution 1.8 Installation and Operation Manual 17 wood should provide several hours of heating. The size of each load can be matched to the amount of

Strona 10

18 Solution 1.8 Installation and Operation Manual 4.3.4 Firing Each New Load Hot Place the new load of wood on and behind the charcoal, and not too

Strona 11 - 3.2.2 Tree Species

Solution 1.8 Installation and Operation Manual 19 4.3.6 Building Different Fires for Different Needs Using the air control is not the only way to ma

Strona 12 - 3.2.4 Piece Size

2 Solution 1.8 Installation and Operation Manual THANK YOU FOR CHOOSING THIS ENERZONE WOOD STOVE As one of North America’s largest and most respected

Strona 13 - 3.2.5 How to Dry Firewood

20 Solution 1.8 Installation and Operation Manual The table below provides a very general indication of the maximum burn cycle times you are likely t

Strona 14 - 4 Operating Your Stove

Solution 1.8 Installation and Operation Manual 21 when the stove is cool by wiping with a damp cloth or paper towel and then drying. Never try to cle

Strona 15 - 4.2 Lighting Fires

22 Solution 1.8 Installation and Operation Manual 5.1.3 Replacing the Door Gasket It is important to maintain the gasket in good condition. After a

Strona 16 - 4.3 Maintaining Wood Fires

Solution 1.8 Installation and Operation Manual 23 Do not abuse the glass door by striking or slamming shut. Do not use the stove if the glass is bro

Strona 17 - 4.3.3 Raking Charcoal

24 Solution 1.8 Installation and Operation Manual Contact your local municipal or provincial fire authority for information on how to handle a chimne

Strona 18

Solution 1.8 Installation and Operation Manual 25 PART B - INSTALLATION 6 Safety Information 6.1 Summary of Installation Cautions and Warnings • THE

Strona 19

26 Solution 1.8 Installation and Operation Manual 6.2 Regulations Covering Stove Installation When installed and operated as described in these inst

Strona 20 - 5.1 Stove Maintenance

Solution 1.8 Installation and Operation Manual 27 CLEARANCES (SINGLE WALL PIPE) CANADA USA A 14’’ (356 mm) 14’’ (356 mm) B 12’’ (305 mm) 12’’ (30

Strona 21

28 Solution 1.8 Installation and Operation Manual    Clearances to combustible materials and floor protection

Strona 22

Solution 1.8 Installation and Operation Manual 29 7.3 Floor protector Your stove has been conceived to prevent the floor from overheating. However, i

Strona 23

Solution 1.8 Installation and Operation Manual 3 Table of content PART A - OPERATION AND MAINTENANCE ... 61 Safety Info

Strona 24 - 5.2.3 Cleaning the Chimney

30 Solution 1.8 Installation and Operation Manual 7.4 Reducing Wall and Ceiling Clearances Safely It is often desirable to reduce the minimum instal

Strona 25 - 6 Safety Information

Solution 1.8 Installation and Operation Manual 31 Clearances for shield construction

Strona 26

32 Solution 1.8 Installation and Operation Manual 7.4.2 Table of Clearance Reduction Percentages Type of shield Clearances may be reduced by these p

Strona 27 - Clearances for mobile homes

Solution 1.8 Installation and Operation Manual 33 8 The Venting System 8.1 General The venting system, made up of the chimney and the connecting pi

Strona 28 -

34 Solution 1.8 Installation and Operation Manual 8.2.2 Factory-built Metal Chimneys in mobile homes For use in a mobile home, this stove is to be co

Strona 29 - 7.3 Floor protector

Solution 1.8 Installation and Operation Manual 35 8.2.3 Masonry Chimneys The stove may also be connected to a masonry chimney, provided the chimney c

Strona 30

36 Solution 1.8 Installation and Operation Manual 8.4.1 Why inside chimneys are preferred Venting systems that rise straight up from the stove flue

Strona 31

Solution 1.8 Installation and Operation Manual 37 There are two reasons why the chimney in the house at right will cold backdraft when it is cold out

Strona 32

38 Solution 1.8 Installation and Operation Manual Some jurisdictions in the United States require that wood stoves have a supply of combustion air fr

Strona 33 - 8 The Venting System

Solution 1.8 Installation and Operation Manual 39 8.6.1 Installation of Single Wall Chimney Connector The chimney connector assembly has been called

Strona 34

4 Solution 1.8 Installation and Operation Manual 5 Maintaining Your Wood Heating System ... 205.1 Stove Maintenance ..

Strona 35 - 8.3 Minimum Chimney Height

40 Solution 1.8 Installation and Operation Manual The rules below are based on those found in the CSA B365 installation code. Please carefully follow

Strona 36

Solution 1.8 Installation and Operation Manual 41 Appendix 1: Installing the Legs or Pedestal The leg or pedestal kit must be assembled to the firebo

Strona 37

42 Solution 1.8 Installation and Operation Manual Leg kit installation: 4- Secure each leg (A) on support (B) using (2) washers (C) and (2) nuts (D)

Strona 38

Solution 1.8 Installation and Operation Manual 43 Pedestal kit installation: Follow step 1, 2 and 3 of the leg kit installation. 5- Secure pedesta

Strona 39

44 Solution 1.8 Installation and Operation Manual Appendix 2: Installing the Door Overlay Sold as an Option In order to complete the assembly of you

Strona 40

Solution 1.8 Installation and Operation Manual 45 Appendix 3: Installing Trims Your freestanding SOLUTION 1.8 wood stove is equipped with decorative

Strona 41

46 Solution 1.8 Installation and Operation Manual Appendix 4: Installing the Optional Air Mate (AC01230) Most freestanding Enerzone wood stoves can

Strona 42

Solution 1.8 Installation and Operation Manual 47 Appendix 5: Installing the Optional Fresh Air Kit (OA10500/AC02090) When installed with a fresh ai

Strona 43

48 Solution 1.8 Installation and Operation Manual Appendix 6: Installation and Use of Optional Air Circulation Fan, and Thermodisc (AC01000/AC02055)

Strona 44

Solution 1.8 Installation and Operation Manual 49  CAUTION: ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE STOVE TO PREV

Strona 45 - Appendix 3: Installing Trims

Solution 1.8 Installation and Operation Manual 5 8.6.1 Installation of Single Wall Chimney Connector ...

Strona 46

50 Solution 1.8 Installation and Operation Manual Appendix 7: Installation of Secondary Air Tubes and Baffle 1- Remove the hatched bricks as per dr

Strona 47 - (OA10500/AC02090)

Solution 1.8 Installation and Operation Manual 51 4- Lock it in place by using a cotter pin on the right side. 5- Repeat step 2 and 3 for the other

Strona 48

52 Solution 1.8 Installation and Operation Manual Note that secondary air tubes (A) can be replaced without removing the baffle board (B). Importan

Strona 49

Solution 1.8 Installation and Operation Manual 53 Appendix 8: Exploded Diagram and Parts List

Strona 50

54 Solution 1.8 Installation and Operation Manual IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your stove,

Strona 51

Solution 1.8 Installation and Operation Manual 55 # Item Description Qty31 24012 CAST IRON LEG WITH LEVELING BOLT 4 31 PL24012PN ENERZONE NICK

Strona 52 - Model Type of tube

56 Solution 1.8 Installation and Operation Manual ENERZONE LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original co

Strona 53

6 Solution 1.8 Installation and Operation Manual PART A - OPERATION AND MAINTENANCE Please see Part B for installation instructions. 1 Safety Informa

Strona 54

Solution 1.8 Installation and Operation Manual 7 2 General Information 2.1 Solution 1.8 Specifications Fuel Type Cordwood Test Standards (safety

Strona 55

8 Solution 1.8 Installation and Operation Manual

Strona 56

Solution 1.8 Installation and Operation Manual 9 2.2 Zone Heating and How to Make it Work for You Your new Solution 1.8 wood stove is a space heat