Intensity
Draft Setting
Low Push Control to end of travel.
Medium Low Pull Control by 3/8” from closed position.
Medium High Pull Control by 3/4” from closed position
High Pull Control to end of travel.
Table 3.4
Closing the draft control down too soon will lower combustion efficiency, and may result in
creosote build-up in the chimney (which could lead to a future chimney fire).
CAUTION: THE ADJUSTMENT RANGE SHOULD NOT BE ALTERED FOR INCREASED FIRING FOR ANY REASON.
DAMPER OPERATION
CLOSED
OPENED
Figure 3.4